High Quality Light Weight Outdoor Duct Armored Single Mode Stranded GYTA Fiber Optic Cable

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Zhejiang
Validity to: Long-term effective
Last update: 2017-08-12 05:19
Browse the number: 194
inquiry
Company Profile
 
 
Product details


1.  Product Description

This specification covers the general requirements and performance of cable, which FOC offered including optical characteristics, mechanical characteristics and geometrical characteristics and etc.


2.  OPTICAL FIBER


Optical fiber characteristics (FPC G.652 FIBER)


Category

Description

Specifications

G.652D
Optical Specifications

Attenuation

@1310nm

≤0.35dB/km

@1383nm

≤0.35dB/km
@1550nm ≤0.22dB/km

Attenuation discontinuity

≤0.05 dB

Attenuation vs. Wavelength

@1285~1330nm

≤0.05 dB/km

@1525~1575nm

≤0.05 dB/km

Zero Dispersion Wavelength

1300~1324nm

Zero Dispersion Slope

≤0.092ps/(nm2.km)

Dispersion

@1310nm

≤3.5 ps/nm.km

@1550nm

≤18 ps/nm.km
Cable Cutoff Wavelength(λcc) ≤1260nm

Effective Group Index of Refraction

@1310nm

1.4675

@1550nm

1.4681

Geometric

Specifications

Mode Field Diameter

@1310nm

9.2±0.6μm

@1550nm

10.4±0.8μm

Cladding Diameter

125±1μm

Cladding Non-Circularity

≤1.0%

Coating Diameter

245±7μm

Coating/Cladding Concentricity Error

≤8μm

Core/Cladding Concentricity Error

≤0.8μm

Mechanical

Specifications

Proof Test level

≥1.0%

Fiber Curl Radius

≥4.0m

Peak Coating Strip Force

1.3~8.9N


3.  OPTICAL CABLE


3.1 Construction of cable



Structure

Unit

Parameter

Fiber count

fibers

2~30

32~60

62~72

74~84

86~96

Element

--

5

5

6

7

8

Loose tube Diameter

mm

Nom.Ф1.8

Nom.Ф2.1

Nom.Ф2.1

Nom.Ф2.1

Nom.Ф2.1

Cores of per tube(no more than)

--

6

12

12

12

12

Cable diameter(Approx.)

mm

9.0

9.9

10.5

11.4

12.0

Weight(Approx.)

Kg/km

79

96

118

129

140

Structure

Unit

Parameter

Fiber count

fibers

98~108

110~120

122~132

134~144


Element

--

9

10

11

12


Loose tube Diameter

mm

Nom.Ф2.1

Nom.Ф2.1

Nom.Ф2.1

Nom.Ф2.1


Cores of per tube(no more than)

--

12

12

12

12


Cable diameter(Approx.)

mm

12.7

13.2

14.1

14.8


Weight(Approx.)

Kg/km

153

165

183

199



*Notice: 8 core: 2tubes, each tube including 4fibers.


3.2 Mechanical characteristics


Tensile strength

Long term

N

600

Short term

N

1500

Crush Resistance

Long term

N

300

Short term

N

1000

Bending Radius

Dynamic

--

≥20×Cable Diameter

Static

--

≥10×Cable Diameter

Operating Temperature

-40 --- +60


3.2 Fiber coding,The color coding of the optical fiber shall be in accordance with Table 3.2.1


No. of fiber

1

2

3

4

5

6

Color of fiber

Blue

Orange

Green

Brown

Grey

White

No. of fiber

7

8

9

10

11

12

Color of fiber

Red

Black

Yellow

Violet

Pink

Aqua


Table3.2.2:Identification of loose tube


No. of tube

1

2

3

4

5

6

Color of tube

Blue

Orange

Green

Brown

Slate

White

No. of tube

7

8

9

10

11

12

Color of tube

Red

Black

Yellow

Violet

Pink

Aqua


4. TEST REQUIREMENTS


No

Item

Test standard

Method

Acceptance criteria

1

Tensile

test

IEC-60794-1-E1

-Max.Tensile strength:1500N

-Sample length:50meters

-Time: 1minutes;

-Fiber strain at maximum

Load: max. 0.15%

-Attenuation increase≤0.10dB

2

Crush

test

IEC-60794-1-E3

-Load: Max.Crush Resistance:1000N

-Time: 1 minutes

-Length:100mm

-No splits or cracks in the outer jacket;

-Attenuation increase<0.10dB,

3

Impact

test

IEC-60794-1-E4

-Impact energy:450g

- Height:1 meter

-Number of impacts: 5

-No splits or cracks in the outer jacket

-Attenuation increase≤0.03dB after the test.

4

Repeated bending

IEC-60794-1-E6

-R=20×cable outer diameter

-1m cable length with 150N weight,30 cycles

- No splits or cracks in the outer jacket

-Attenuation increase ≤0.03dB after the test.

5

Torsion

test

IEC-60794-1-E7

-1m cable length with 150N weight

-±90 degrees, 10 cycles

- No splits or cracks in the outer jacket

-Attenuation increase ≤0.03B after the test.

6

Bending

test

IEC-60794-1-E11

-Diameter of mandrel:20×D

-Number of turns/helix:10

-Number of cycles: 5

-No damage to the outer jacket

- No fiber break

-Reversible

7

Temperature cycling test

IEC-60794-1-F1

-Temperature step: +20℃→-40℃→+60℃→-40℃→

+60℃→+20℃

-Time per each step: 12 hrs

-Number of cycles: 2 cycles

-Attenuation variation for reference value(the attenuation to be measured before test at +20±3℃) ≤0.10dB,


5.  PACKING AND DRUM


5.1 The cable is wound on a non-returnable wooden drum. Both ends of cable are securely fastened to drum and sealed with a shrinkable cap to prevent ingress of moisture. The following information shall be marked on the outer sheath of the cable at an interval of about 1 meter.

-   Cable type and number of optical fiber

-   Manufacturer name

-   Month and Year of Manufacture

-   Cable length

The sequential number of the cable length shall be marked on the outer sheath of the cable at an interval of 1meter ± 1%.


5.2 Drum marking, Each side of every wooden drum shall be permanently marked in a minimum of 2.5~3 cm high lettering with following:

-  Manufacture name and logo

-  Cable length

-  Cable type and number of fibers

-  Roll way

-  Gross and net weight


-End of Specification-